WINDISOURFRIEND.DE ≡ Cutting Scissors Vartalonhoito Levers Outdoor Spots
  • Ac Only Clamps

  • FLUKE i3000S-24 Flex AC 3000A Current Clamp

FLUKE i3000S-24 Flex AC 3000A Current Clamp

$51.23 $85.04
The Fluke i3000s-24 Flex is an ac current clamp utilizing the Rogowski principle. It can be used to measure currents from 3 to 3000 AC when used in conjunction with oscilloscopes, recorders or data loggers. The flexible and lightweight measuring head allows quick  and easy installation in hard to reach areas. The i3000s Flexprovide a low voltage 3 V AC  output that is proportional to the current being measured. The Probes provide full-scale direct readings for 30 A, 300 A, and 3000 A. Fluke i3000s Flex  Electrical Specifications Current ranges 30 A 300 A 3000 A AC rms Output sensitivity (AC-coupled) 100 mV 10 m 1 mV per A Load impedance 100 kΩ minimum Accuracy at 25°C ±1% of range (45 Hz to 65 Hz) Linearity 10% to 100% of range ±0.2% of reading Noise 8 mV AC rms (30 A) 2 mV AC rms (300 A, 3000 A) Frequency range 10 Hz to 50 kHz (-3 dB) Phase error < ±1° (45 Hz to 65 Hz) ±10° (at 20 kHz) Position sensitivity with cable > 25 mm from the coupling ±2% of range External field with cable > 200 mm from the head ±1% of range Power supply 2 x AA/MN 1500/LR6 Alkaline, 400 hours, low battery indicator or dedicated external power supply Temperature coefficient ±0.08% of reading per °C Working voltage see safety standards section 600 V AC rms or DC General Specifications Head circumference 610 mm Head cable diameter 14.3 mm Head bend radius 38.1 mm Cable length (head to electronics) 2 m Output connection 0.5 m cable terminated with safety BNC connector. Supplied with 4mm safety plug adapter Operating temperature range -20°C to 90°C (-4°F to 190°F) (head) -20°C to 85°C (-4°F to 185°F) (electronics) Strong temperature range -40°C to 105°C (-40°F to 221°F) (head) -20°C to 85°C (-4°F to 185°F) (electronics) Operating humidity 15% to 85% (non-condensing) Weight 180 g  (head) 190 g (electronics) Safety standards BS EN 61010-1: 2001 BS EN 61010-2-032: 2002 BS EN 61010-031: 2002 600 Vrms, Category III, Pollution Degree 2 Use of the probe on uninsulated conductors is limited to 600 V AC rms or DC and frequencies below 1 kHz EMC standards EN 61326: 1998 A1, A2, and A3 Head cable length (double insulated) 610 mm
Ac Only Clamps

Ac Only Clamps

  • Fluke T6-1000 PRO Electrical Tester with Visual Continuity™
    $41.83 $80.31
  • Fluke T6-1000 Electrical Tester with FieldSense Technology
    $68.26 $129.01
  • FLIR CM42 400A AC Digital TRMS Clampmeter
    $35.33 $60.06
  • FLIR CM57-2 Flexible Clamp Meter with 18-inch Coil, Bluetooth Connectivity and Dual LED Work Lights – Ideal for Current Measurements in Tight Spots
    $38.42 $55.71
  • Fluke T6-600 Electrical Tester with FieldSense Technology
    $67.14 $87.28
  • FLUKE T5-600 Electrical Tester CAT III 600V
    $43.14 $60.83
  • FLUKE T5-1000 Electrical Tester CAT III 1000V
    $54.55 $80.73
  • FLUKE i3000S-24 Flex AC 3000A Current Clamp
    $51.23 $85.04

© 2026 - WINDISOURFRIEND.DE